Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)
A. -v3-64bit-identifiersYou created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive anout of apace error message on your host.
What would cause this error?
A. The maximum number of volume constituents has been reached in the ONTAP software.You have connection Issues from a Linux host to an AFF A400 FC LUN. You are asked by support to run the NetApp sanlun command to provide troubleshooting information.
Which NetApp software package must be installed on the host?
A. Virtual Storage ConsoleYou recently discovered the error message shown below in your ONTAP logs.

What should be your first action to correct this Issue?
A. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol volume.A customer reports that while Installing Windows updates on their external Vscan servers, clients couldnot access any files on their CIF-S SVM. The problem disappeared after the update process was completed. The customer wants to prevent this issue from happening during the next patch window.
In this scenario, what are two ways to accomplish this task? (Choose two.)
A. Enable the -scan-mandatory flag in the Vscan policy.When an administrator tries to create a share for an existing volume named voll, the process fails with an error.

Referring to the exhibit, what Is the reason for the error?
A. The volume must have a type of DP.Your customer has mounted an NFS SVM from a Linux client unci performance is very poor. The customer is certain that they have jumbo frames enabled. They have verified an MTU of 9000 on both the Linux client and the broadcast domain on the NetApp ONTAP 9.8 cluster.

Referring to the exhibit, which ONTAP command will help isolate a possible MTU mismatch?

A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment. What Information would you tell your customer in this scenario?
A. The AUSO feature cannot be activated due to a non-mirrored aggregate.You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster running NetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event log has the message shown
below.
ISCSI: network interface identifier disabled for use; incoming connection discarded
In this scenario, what is the cause of this connection issue?
A. iSNS is not enabled on the storage virtual machine.A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced a site outage and wants to know why the MetroClusler configuration did not switch over to the other site. What are two reasons for this problem? (Choose two.)
A. There was a failed PSU inthe switchover site.Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-593 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.