  • Question 51:

    You are troubleshooting a CIFS connection issue that is reported by some users. You decide to collect a packet trace.

    In this scenario, after you generate the packet trace, where do you find the trace file?

    A. /packet_traces of the node hosting the LIF
    B. /etc/log/packet_traces of the node hosting the LIF
    C. /etc/log/mlog/packet._traces Of all nodes
    D. /vol0/paclcet_traces of the CIFS SVM

  • Question 52:

    A customer is calling you to troubleshoot why users are unable to connect to their CIFS SVM.

    Referring to the Information shown in the exhibit, what Is the source of the problem?

    A. Thev1db database is offline.
    B. The aggregate aggr2 has a failed disk.
    C. The databases On Node03 must be Switched from secondary to master.
    D. The broken disk in Node03 is the source of the problem.

  • Question 53:

    You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated fromNode 2, interface e0b.

    In this scenario, what should you do first to solve this problem?

    A. Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.
    B. Replace the motherboard on Node 2.
    C. Replace both NetApp CN1610 switches.
    D. Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.

  • Question 54:

    Referring to the exhibit

    What do you need to do to return the MetroCluster to a normal state?

    A. Enter the metroclustor switchback command on Site B.
    B. Enter the metrocluster switchback command on Site A.
    C. Enter the storage failover giveback command on Site B.
    D. Enter the storage failover giveback command on Site A.

  • Question 55:

    A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G Ethernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1. You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.

    What is the cause of the customer's problem?

    A. The cable is plugged in upside down.
    B. The incorrect cable is used.
    C. The ports are configured for 4x10Gbit instead of 40Gbit.
    D. The port has an incorrect SFP inserted.

  • Question 56:

    Which two statements about NetApp Cloud Volumes ONTAP licenses ate true? (Choose two.)

    A. Having an Essentials package enables you to convert to another licensing option.
    B. Capacity-based license packages support only single-node configurations.
    C. BYOL licenses are purchased directly from NetApp.
    D. AWS Marketplace contracts cannot be mixed with BYOL.

  • Question 57:

    You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show command for more Information. You notice the "Urge" column has non-zero values.

    In this scenario, which statement is true?

    A. The aggregate is completely full.
    B. The constituent volumes are out ofInodes.
    C. The data placement is uneven.
    D. The constituent volumes are completely full.

  • Question 58:

    You have recently discovered that NetApp ONTAP Cloud Manager is not sending AutoSupport messages to NetApp. In this scenario, what would solve this Issue?

    A. Verify that your AWScredentials are correctly added to Cloud Manager.
    B. Verify that your NetApp Support site credentials are correctly added to Cloud Manager.
    C. Verify that your data LIFs allow traffic to mysupport .netapp.com on port 443.
    D. Verify that the inbound and outbound rules allow AutoSupport on port 80.

  • Question 59:

    A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log. Which FIFO message Is useful for Investigating this Issue?

    A. before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A
    B. BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11
    C. before Reset BBSP:C=00 L=00 FIFO:
    D. ONTAP Shutdown BBSP:C=00 L=2F FIFO:

  • Question 60:

    You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They provided you packet traces from the controller and client. Analysis of these traces shows an average service response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in the same time period.

    In this situation, what would be your next step?

    A. The cluster is responding slowly and requires further investigation using performance archives.
    B. The client that reports high latency should be investigated.
    C. The cluster interconnects should be investigated.
    D. A sync core should be triggered.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-593 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.