Which three factors should you consider before you install an E2860 in a data center? (Choose three.)
A. current drawYou are setting up asynchronous mirroring between two E2860 systems.
In this scenario, which two prerequisites are required to complete the setup? (Choose two.)
A. Both the primary and secondary systems must be using the same subnets for mirroring connections.A customer wants to manage an E-Series system over a secure connection between the system and a server. During implementation, you are asked to fulfill this installation requirement. In this scenario, which three actions are required to complete this task? (Choose three.)
A. Disable the legacy management interface on the systemA company has a duplex E-Series system that is operating in a highly tuned environment. Load distribution between the controllers has been manually set up to achieve a specific distribution based on unique workload characteristics. In this scenario, to maintain this load distribution over time, which E-Series feature should be disabled?
A. Storage Load BalancerA company is using the Federal Information Processing Standard (FIPS) on all volume groups. However, one volume group failed a security audit. In this scenario what would cause a volume group to fail the security audit?
A. An FDE drive was added as a spare in the volume groupWhich two actions must be performed to enable iSCSI multipathing on Windows for NetApp E-Series systems? (Choose two.)
A. Set up iSCSI IP addresses on the E-Series system and the Windows hostA customer is running several EF570 systems and uses the ability of the EF-Series systems to run two host protocols at the same time. You are installing a new EF570 that uses the NVMe protocol for a high performance computing application. The controller on-board ports will not connect, but the HIC ports are working fine.
In this scenario, what is the problem?
A. The on-board host ports are disabledWhich data protection strategy has the most overhead capacity as a percentage of the total capacity?
A. RAID 10An administrator is asked to provision a 1 TB volume to hold non-critical temporary data for a seismic-analysis application. The volume requires the highest possible IOPS. In this scenario, which configuration would satisfy this requirement?
A. RAID 6 Dynamic Disk Pool with a 256 KiB segment sizeYour company has deployed an E2824 and has decided to change the host protocol from iSCSI to FC. You use the storage array profile to review the installed SFPs. In this scenario, which set of supported data rates indicates that you are using dual-purpose SFPs?
A. 25 Gbps, 10 GbpsNowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-515 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.