Cisco 300-615 Online Questions & Answers

  • Question 281:

    Refer to the exhibit.

    UCS-1 fails to connect to the storage array. Which action resolves the issue?

    A. Set the FI-A mode to FC End Host mode.
    B. Enable N9K-1 mode to N-Port ID Virtualization.
    C. Configure N-Port ID Virtualization on FI-A.
    D. Implement N-Port Mirtualization on N9K-1.

  • Question 282:

    A Cisco UCS B-Series Blade Server is configured to boot a VMware ESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected, but the server fails to boot from the SAN. Which action resolves the problem?

    A. Set the boot LUN to the highest LUN ID in the storage array.
    B. Set the boot LUN to the lowest LUN ID in the storage array.
    C. Set the same WWNN pools for vHBA adapters.
    D. Set the same WWPN pools for vHBA adapters.

  • Question 283:

    Refer to the exhibit.

    A network engineer creates an EEM script to trigger an SNMP notification when a user enters configuration mode, but the trap is not received when the condition is met. Which action resolves the issue?

    A. Append action 2.0 event-default to the script
    B. Append action 2.0 cli "conf t" to the script
    C. Modify snmp-trap strdata "Configuration changed" to syslog msg Configuration changed
    D. Modify cli match "conf t" to "snmp match "conf t"

  • Question 284:

    Refer to the exhibit. A network engineer must implement an EEM script to generate SNMP traps when configuration mode is entered. After the configuration was applied, the configure terminal command was blocked. Which action resolves the issue?

    A. Add the event-default action statement.
    B. Implement an override system policy.
    C. Use an event manager policy module script.
    D. Enable event syslog tags.

  • Question 285:

    Refer to the exhibit.

    An engineer cannot log in to the Cisco IMC page of the Cisco UCS C220 server. Which action resolves the issue?

    A. Se the FQDN of the Cisco IMC webpage login page instead of the IP address for the connection to be secure.
    B. Use the DNS of the Cisco IMC webpage login page instead of the IP address for the connection to be secure.
    C. Replace the self-signed certificate that is installed on the Cisco IMC with a server certificate that is signed from the client corporate certificate.
    D. Replace the self-signed certificate that is installed on the Cisco IMC with a user certificate that is signed from the client corporate certificate.

  • Question 286:

    Refer to the exhibit.

    A Cisco UCS Director appliance that has the Cisco UCS Director Bare Metal Agent installed fails to boot from the PXE. TFTP and the Bare Metal Agents are running. Which action do you take to resolve the issue?

    A. Restart the Cisco UCS Director Bare Metal Agent services.
    B. Restart the TFTP service.
    C. Reinstall the Cisco UCS Director Bare Metal Agent.
    D. Reinstall TFTP.

  • Question 287:

    Refer to the exhibit. An engineer fails to perform a database merge between two Cisco MDS 9000 Series Switches named switch-1 and switch-2. Which set of commands resolves the issue?

    A. On switch-1, run the device-alias database pwwn 21:01:01:01:01:01:01:01 command. On switch-2, run the device-alias database pwwn 21:01:01:01:01:01:01:02 command.
    B. On switch-2, run the device-alias rename A1 A2 command. On switch-2, run the device-alias database pwwn 21:01:01:01:01:01:01:01 command.
    C. On switch-1, run the device-alias rename A1 A2 command. On switch-2, run the device-alias database pwwn 21:01:01:01:01:01:01:01 command.
    D. On switch-1, run the device-alias rename A3 A123 command. On switch-2, run the device-alias rename A1 A123 command.

  • Question 288:

    Refer to the exhibit.

    customer reports that all Intra-EPG isolation stopped working within a bare-metal tenant. Postman is running on a machine to get information from the APIC in case of orchestration failure. Which action resolves the issue?.

    A. Match encap="vlan-10" and primaryEncap="vlan-110"
    B. Change pcEnfPref="unenforced" to pcEnfPref="enforced"
    C. Remove primaryEncap="vlan-110" from the specific port path
    D. Modify the GET command to reference the valid path for the managed object

  • Question 289:

    Refer to the exhibit.

    An engineer is experiencing a problem when running a Docker container inside the Cisco Nexus 9000 bash shell. Which action resolves the issue?

    A. Add a new nameserver
    B. Connect to bash as a different user
    C. Change VRF to management
    D. Configure the mgmt0 interface

  • Question 290:

    An engineer troubleshoots a Cisco UCS B-Series environment and discovers that the status of the CNA is degraded in the CLI and the Cisco UCS Manager GUI. What should be done to resolve the issue?

    A. Seat the blade server correctly in the chassis.
    B. Install the adapter firmware version that is compatible with Cisco UCS Manager.
    C. Install the server air baffles correctly.
    D. Use the supported adapter on that server model.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only Cisco exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your 300-615 exam preparations and Cisco certification application, do not hesitate to visit our Vcedump.com to find your solutions here.