D-PSC-MN-01 Exam Details

  • Exam Code
    :D-PSC-MN-01
  • Exam Name
    :Dell GenAI Foundations Achievement
  • Certification
    :EMC Certifications
  • Vendor
    :EMC
  • Total Questions
    :101 Q&As
  • Last Updated
    :Jul 15, 2026

EMC D-PSC-MN-01 Online Questions & Answers

  • Question 81:

    What is the isi diagnostics gather command used for?

    A. Diagnose the CPU.
    B. Diagnose the TPM
    C. Gather performance data.
    D. Gather cluster logs

  • Question 82:

    Which port slot provides management functionality on a PowerScale F600?

    A. PCle slot 3
    B. PCle slot 1
    C. rNDCstot
    D. PCle slot 2

  • Question 83:

    A platform engineer has built the rack for a Dell EMC PowerScale cluster. While unpacking the components, the engineer notices that the ShockWatch meter has been activated.

    A. Deactivate the ShockWatch meter
    B. Reset the ShockWatch meter
    C. Contact Dell EMC PowerScale Technical Support
    D. Proceed with unpacking the components

  • Question 84:

    A platform engineer needs to swap an NVDIMM battery. What prerequisite conditions are required to prevent data loss when removing the NVDIMM battery?

    A. None - the NVDIMM battery is hot-swappable
    B. The node is switched off and must be removed from the power feed
    C. LEDs on the NVDIMM battery must be off
    D. Node, LEDs on the node, LEDs on the NVDIMM, and LEDs on the NVDIMM battery must be off

  • Question 85:

    Refer to the exhibit.

    An engineer replaced the drive in C1. They run the isi devices drive list command and obtain the output that is shown. What action must the engineer take?

    A. Run the 1 = 1 devices drive add c1command.
    B. Run the isi devices drive format C1command.
    C. Contact Dell support.
    D. Update the drive firmware.

  • Question 86:

    A company must ensure their PowerScale cluster can handle many active client connections. What must they do when designing their system?

    A. Include a Leaf-Spine backend network
    B. Use the P100 node.
    C. Add maximum RAM in each node.
    D. Add L3 cache to the nodes.

  • Question 87:

    A client plans to reconnect to a cluster automatically without Interruption.

    Which two upgrade methods can be used to complete the upgrade while file service is still available to the client?

    A. Parallel upgrades
    B. Simultaneous upgrades
    C. Rolling upgrades
    D. Automated upgrades

  • Question 88:

    DRAG DROP

    What Is the correct order of steps to Install a PowerScale Gen6 in a rack?

    Select and Place:

  • Question 89:

    What should the platform engineer pre-check when installing Dell EMC PowerScale Gen 6 nodes in a customer-provided rack?

    A. PDUs are located on opposite sides of the rack
    B. Rack is leveled using the front legs first and the rear legs second
    C. Rack has full earth ground and is properly bolted to the floor
    D. Rack has a minimum of two PDUs

  • Question 90:

    Which versions are supported and can be upgraded to Dell EMC PowerScale OneFS 8.2?

    A. OneFS 7.0.1.0 ?7.0.2.0
    B. OneFS 7.1.0.0 ?7.1.1.1
    C. OneFS 7.2.0.0 ?7.2.0.1
    D. OneFS 7.2.1.0 ?7.2.1.1

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your D-PSC-MN-01 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.