Click the Exhibit button.

An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The hosts are not configured to connect to any other SVM. Which action should be performed to restore multi-path connectivity to the LUNs in this scenario?
A. Create LIFs on SVM "C" for host connectivity.You have three Windows servers and one Linux server, each with dual-ported HBAs that are connected into a dual fabric. In this scenario, what is the minimum number of zones that you need to create within each fabric switch?
A. 8An administrator wants to implement FCoE for connectivity of an AFF A200 using VLAN 3011 for fabric traffic across VSAN 11. When configuring the Nexus switches for FCoE connectivity, which two actions are required? (Choose two.)
A. Create a new virtual FC interface and bind the physical interface to it.An administrator has an AFF A200 cluster at their primary site that is used for FC connectivity to servers. For disaster recovery purposes they want to start replicating their data to another AFF A3Q0 cluster In a secondary location. The AFF
A300 is In a site that has no FC or FCoE capable switches, and is currently only used for CIFS dat A cluster peering relationship already exists between the two clusters.
Which three additional actions are needed for the data to be ready for access from hosts at the secondary site? (Choose three.)
A. Create zones with the appropriate initiators and targets for the secondary site.A storage administrator created a LUN using two ports on a storage system. Later, additional LUNs were added to the same node as the original LUN. After a while, the performance of the original LUN dropped beyond an acceptable level. What would you advise to remedy the Issue?
A. Add an additional switch between the hosts and cluster.Click the Exhibit button.

You have a LUN owned by Node 01 and mapped using the default Selective LUN Map (SLM) configuration. You want to enable your host to access this LUN and facilitate future maintenance. Which best-practice zone configuration accomplishes this task?

You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage.
What are three reasons for this problem? (Choose three.)
A. The protocol has not been enabled on the NetApp cluster.Exhibit.

A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit. The zones are implemented on the switches shown below.

IF all the nodes are in the SLM reporting nodes list, how many paths per LUN should the customer expect when simulating a node failure by powering off Node 04?
A. 4 pathsAn administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance mode. When the maintenance was completed, the two hosts do not have access to the new datastore, but they have access to other datastores on the same volume.
In this scenario, what caused this result?
A. The VSC cannot create datastores while hosts are in maintenance mode.Exhibit.

You want to map a LUN to a server.
To which SAN object is the highlighted value in the exhibit added?
A. LUNNowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-509 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.