  • Question 41:

    Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has the appropriate storage controller installed and two 12Gb SAS switches installed in the first fabric.

    The customer reports that the compute nodes cannot access the storage module.

    What will you verify first when troubleshooting this problem?

    A. If the SAS logical interconnect is a part of the logical enclosure and has a healthy state.
    B. If the D3940 module is imported in a managed state that allows volume provisioning.
    C. If there is at least one iSCSI network configured that will provide access to the module.
    D. If the D3940 storage module is properly licensed through the HPE OneView interface.

  • Question 42:

    Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC). What should you check during troubleshooting process?

    A. If HPE OneView credentials are added in vCenter Server
    B. If an compute nodes are added to the vCenter Server
    C. If the HPE Oneview instance Is integrated with HPE OV4VC.
    D. If vCenter Server is licensed in the HPE Oneview interface

  • Question 43:

    You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group What should you check to fix the issue?

    A. if both FiexNICs are configured with the same speed
    B. If the logical enclosure is built on at least three HPE Synergy frames
    C. if both FiexNICs are connected to different networks
    D. if the logical enclosure is configured with redundant master modules

  • Question 44:

    DRAG DROP

    Put the steps of the HPE infosight flow in the correct order.

    Select and Place:

  • Question 45:

    Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customer's needs?

    A. Rack Management Controller for nPar management
    B. HPE Superdome Flex Grid licenses enabling connectivity between chassis
    C. At least Tour HPE Persistent Memory DIMMs per nPar
    D. One base chassis and three expansion chassis with licenses

  • Question 46:

    As a result of the troubleshooting process, you recommend replacing, HPE Synergy Composer modules which HPE Synergy Composer 2 Why would you recommend this change?

    A. HPE Composer 1 running HPE OneView 5 2 or later can support only 12 frames within a single management nog
    B. HPE Composer 2 can support more than the maximum 21 frames that are supported with HPE Composer 1 and HPE OneView.
    C. HPE Composer 2 provides access to 105 interface that can be used for full management of HPE Composer 2 remotely
    D. HPE Composer 1 cannot support remote frames, which doubles the configuration and management procedures effort

  • Question 47:

    Your customer manages an HPE Synergy platform using HPE OneView 5.6. To leverage new functionalities, the customer wants to update HPE OneView to version 61 Which statement about this update process is true?

    A. To update to 6,1, the customer has to first update to 6 0, which is a milestone edition.
    B. The customer can update directly to 6,1, but HPE OneView downtime will be longer.
    C. Before updating to 6,1, customer should increase memory size on the HPE Composer.
    D. The customer must check the HPE Composer version, as 61 is supported only with HPE Composer2.

  • Question 48:

    HOTSPOT

    You configured a virtual machine cluster using the HPE Storage Integration Pack for VMware vCenter.

    Click the option in the SSMC main menu that you can use to verify whether a virtual storage operation is properly created on HPE Primera or 3PAR.

  • Question 49:

    Your customer plans to deploy VMware vSAN using D3940 Storage Modules. Which statement about this solution is true?

    A. The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
    B. To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
    C. For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
    D. All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured

  • Question 50:

    Which statement about HPE Superdome Flex 280 is true?

    A. It supports 2 to 8 sockets in 2-socket increments.
    B. it cannot be managed using HPE OneView.
    C. It must be equipped with at least 768 GB of memory.
    D. It can support up to two nPars with an external RMC.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only HP exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your HPE0-S59 exam preparations and HP certification application, do not hesitate to visit our Vcedump.com to find your solutions here.