642-035 Exam Details

  • Exam Code
    :642-035
  • Exam Name
    :Troubleshooting Cisco Data Center Unified Computing
  • Certification
    :Cisco Certifications
  • Vendor
    :Cisco
  • Total Questions
    :167 Q&As
  • Last Updated
    :Dec 09, 2021

Cisco 642-035 Online Questions & Answers

  • Question 101:

    For a KVM session to be successful, which two of these need to be done? (Choose two.)

    A. The Cisco IMC IP address needs to be assigned on the Admin tab.
    B. The Cisco IMC IP address needs to be in the same subnet as the management IP.
    C. The Cisco IMC needs to be upgraded to the same version as the UCS Manager.
    D. The server needs to be fully discovered.

  • Question 102:

    A customer is configuring VSANs in a Cisco UCS domain. After configuring the VSANs 3840, 3841, and 3842 in FC end-host mode, the customer sees that these VSANs are not operational and that Cisco UCS Manager is raising faults. What is the cause of this problem?

    A. VSANs 3840, 3841, and 3842 should be in the allowed list on the trunk to clear the fault.
    B. VSANs 3840 to 4079 cannot be used in Fibre Channel end-host mode in a Cisco UCS domain.
    C. The fabric interconnect needs to be configured in switching mode and the VSANs need to be allowed on the trunk.
    D. Use the UCS CLI to clear the fault on the VSAN trunk to forward the VSANs with faults.

  • Question 103:

    After migrating a server that is configured with dynamic vNICs, Cisco UCS Manager assigns new dynamic vNICs to the server. If you had been monitoring traffic on an original dynamic vNIC, what must you do when the server comes back up?"

    A. Reassign the dynamic vNIC back to the old configuration.
    B. Nothing; Cisco UCS Manager will take over.
    C. Reassign the service profile back to the master one.
    D. Remove and reconfigure the dynamic vNIC.
    E. Reassign the monitoring source.

  • Question 104:

    Which two types of ports does end host mode switching have? (Choose two.)

    A. VSS
    B. border
    C. router
    D. server
    E. STP
    F. client

  • Question 105:

    On a Cisco Nexus 5000 Series Switch, which two options are valid traffic sources that can be monitored, when configuring a SPAN session for a port channel?

    A. egress and the SAN port channel only
    B. ingress and the SAN port channel only
    C. ingress and egress only
    D. ingress, egress, and the SAN port channel

  • Question 106:

    You have blade servers that run VMware ESXi. Which two tasks do you perform to ensure that all of the components in the Cisco UCS environment use jumbo frames? (Choose two.)

    A. Use a QoS policy for the jumbo frames.
    B. Configure the MTU on the vSwitch.
    C. Configure the fabric interconnect to support 9500-byte frames.
    D. Configure the MTU on the vNIC.
    E. Configure a QoS policy on the vSwitch.

  • Question 107:

    You attempt to perform an ESXi update on a Cisco UCS C250 server, but the update does not recognize the NICs. You must perform the update as quickly as possible. Which step must you do first?

    A. Check the UCS compatibility matrix and replace the NIC with a supported one.
    B. Reconfigure the NIC ID on the LOM.
    C. Update the LOM firmware by using the Cisco Host Update Utility.
    D. Update the NIC firmware by using the Cisco Host Update Utility.

  • Question 108:

    Refer to the exhibit. What does this adapter output indicate?

    A. The target of the configured zone does not match the target of the configured boot order.
    B. The port types between the target and initiator are incorrectly configured.
    C. The target device configuration is not allowing the initiator to access the LUN.
    D. The configured initiator LUN ID does not match the configured target LUN ID.

  • Question 109:

    Which protocols can be used to send to Cisco TAC (Technical Assistance Center) the show tech-support command output information about the Cisco UCS domain? (Choose two.)

    A. TFTP
    B. FTP
    C. SCP
    D. Telnet
    E. SecureTelnet

  • Question 110:

    A customer is configuring the dynamic vNIC connection policy in a Cisco UCS domain. Why is the dynamic vNIC policy required?

    A. It is only required if you are configuring VM-FEX.
    B. It is only required if you are configuring Adapter-FEX.
    C. It is mainly for the Cisco UCS Manager to communicate with the fabric interconnect.
    D. It is required for Cisco UCS instances that include servers with VIC adapters on which you have installed VMs and configured dynamic vNICs.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only Cisco exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your 642-035 exam preparations and Cisco certification application, do not hesitate to visit our Vcedump.com to find your solutions here.