NetApp NS0-502 Online Questions & Answers

  • Question 101:

    A company has a Fibre Channel environment and wants to connect a new host in a remote data center using 50/125um OM2 multi-mode fiber cable and needs to support 2 Gb speeds. What is the maximum distance of the cable run supported in this situation?

    A. 50/125um OM2 multi-mode fiber cable supports up to 500 meters at 2 Gb.
    B. 50/125um OM2 multi-mode fiber cable supports up to 10000 meters at 2 Gb.
    C. 50/125um OM2 multi-mode fiber cable supports up to 150 meters at 2 Gb.
    D. 50/125um OM2 multi-mode fiber cable supports up to 300 meters at 2 Gb.

  • Question 102:

    Which option needs to be set on a LUN to guarantee that it cannot be affected by other LUNs in the volume?

    A. Volume Guarantee
    B. Volume Space Reserved
    C. LUN Reservation Disabled
    D. LUN Reservation Enabled

  • Question 103:

    A dual controller FAS3100 series is connected to a dual fabric with two active target ports per fabric in a single-image cfmode, and uses a single portset. What is the number of paths for ten LUNs on a single host with one connection to each fabric?

    A. 10
    B. 20
    C. 30
    D. 40
    E. 80

  • Question 104:

    Which utility on Solaris 10 can be used to collect information about firmware and driver versions for a Qlogic QLAxxx/QLExxxx HBA?

    A. EMutil
    B. SANutil
    C. cfgadmin
    D. SANsurfer
    E. HBAnywhere

  • Question 105:

    Which FC SAN topology provides the best performance and scalability?

    A. cascade
    B. core-edge
    C. full mesh
    D. partial mesh

  • Question 106:

    You have a Windows 2003 host using the NetApp ONTAP DSM MPIO environment with a FAS6000 high availability configuration running single image cfmode.When you disconnect a cable from the FC switch to a storage target port, how will the I/O fail over?

    A. I/O will fail over to any port on the original controller but NOT on the partner controller that is part of the associated portset. Choice of path will be controlled by the host's MPIO weighting table.
    B. I/O will fail over to any port on either controller that is part of the associated portset. Choice of path will be controlled by the host's MPIO weighting table.
    C. I/O will fail over to any port on the original controller that is part of the associated portset. Choice of path will be controlled by NetApp storage system igroup settings.
    D. I/O will fail over to any port on either controller that is part of the associated portset. Choice of path will be controlled by NetApp storage system igroup settings.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-502 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.