Performance analysis on a VMAX3 has shown that the current workload is 15,000 IOPS at an average response time of 13 ms. Workload will increase to 30,000 IOPS.
What will be the response time expectation?
A. 14 ms
B. Between 13-26 ms
C. 26 ms
D. Greater than 26 ms
Which SYMCLI command can be used to confirm that eDisk have been created when using FAST.X?
A. symcfg
B. symdisk
C. symaccess
D. symsan
A company is using SRDF/AR Multi-Hop as a disaster recovery solution. Their primary application requires 27.3 TB on their primary site. How much storage capacity is required on the third site?
A. Only 27.3 TB
B. 27.3 to 54.6 TB
C. Only 54.6 TB
D. Greater than 54.6 TB
Which special considerations are required for non-ALUA arrays and FAST.X?
A. Non-ALUA Controllers are not supported
B. Remote Controllers can only be connected to a single port on the VMAX3 array
C. Remote Controllers must be zoned to ports on different directors
D. Remote Controllers must be zoned to ports on a single director
If an XtremIO external tier is placed in its own Storage Resource Pool, which SLO is associated with the external tier?
A. Platinum
B. Silver
C. Gold
D. Optimized
Alerts are required to track high I/O response times for a specific storage group. I/O response times greater than 15 ms require next day analysis. I/O response times greater than 20 ms require immediate intervention.
Which alert settings are required?
A. 1st level
Which parameter values will result in a Static Cache Partition in a VMAX All Flash array?
A. Min=30%, Target=30%, Max=30%
B. Min=30%, Target=30%, Max=80%
C. Min=30%, Target=60%, Max=60%
D. Min=30%, Target=60%, Max=80%
Performance analysis on VMAX3 FE ports have shown that a large number of QFULL responses were returned to their best performing hosts. However, other hosts suffered from high response times.
What needs to be configured in order to lower the high response times?
A. Decrease the queue depth of the poor performing hosts
B. Increase the queue depth for all hosts
C. Set similar queue depths for all hosts
D. Increase the queue depth of the best performing hosts
An existing single engine VMAX3 with two FC ports configured for remote replication will be adding FAST.X to a CloudArray. Currently the array is configured with 32 FC ports which are all in use.
Which steps are required to support a minimum connectivity to the CloudArray?
A. Identify a port on each director to be used for the DX emulation Remove replication from any devices on the selected ports Delete any volumes presented to those ports
B. Identify two ports on each director to be used for the DX emulation. Stop all remote replication Delete any volumes presented to those ports.
C. Identify two ports on a single director to be used for the DX emulation Remove any masking entries related to the director ports
D. Identify two ports on each director to be used for the DX emulation Remove any masking entries to the director ports.
By default, how many days of the data are retained if Unisphere for VMAX is configured with a Root Cause Analysis Interval of 10 minutes?
A. 15
B. 30
C. 45
D. 60
Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your E20-807 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.