E20-616 Exam Details

  • Exam Code
    :E20-616
  • Exam Name
    :Symmetrix Installation and Troubleshooting Specialist
  • Certification
    :EMC Certifications
  • Vendor
    :EMC
  • Total Questions
    :113 Q&As
  • Last Updated
    :Jul 08, 2026

EMC E20-616 Online Questions & Answers

  • Question 81:

    A new customer has purchased a VMAX 40K array. During implementation they explain requirements for one application that requires a point-in-time copy of the primary volumes every 2 hours, and retention for three days. The change rate is expected to be low.

    Which replication solution should be recommended?

    A. TimeFinder/Snap
    B. TimeFinder/Clone
    C. TimeFinder/VP Snaps
    D. TimeFinder/Mirror

  • Question 82:

    A CE is dispatched to perform an FCO replacing multiple SPS. After logging into a Symmetrix VMAX 40K running Enginuity 5876.159.102 Simplified SymmWin is automatically launched. How should the CE proceed?

    A. Close Simplified SymmWin and select SymmWin from the desktop, then select Procedure Wizard
    B. Close Simplified SymmWin and select SymmWin from the desktop, then select Replace Bad FRU
    C. Log off then log on using a Break Fix Credential
    D. Simplified SymmWin does not support VMAX 40K

  • Question 83:

    A customer using a VMAX 20K containing 2 standard storage bays, each containing 90 drives wants to expand their capacity to 120 drives. What is the least expensive way to expand the existing configuration, but still a good choice for optimal performance in this configuration?

    A. Add four DAEs to each storage bay, each containing 15 drives
    B. Add eight DAEs to the first storage bay, each containing 15 drives
    C. Add two storage bays, one to each loop and each bay containing four DAEs with 15 drives each
    D. Add one storage bay containing eight DAEs with 15 drives each to the first loop

  • Question 84:

    How many Management Modules are installed in a 6 bay VMAX 10K (987)?

    A. 8
    B. 12
    C. 6
    D. 4

  • Question 85:

    What is the vault hyper size in GB for configuring a new VMAX 20K?

    A. 5
    B. 9
    C. 4.5
    D. 0.5

  • Question 86:

    In a cascaded SRDF/EDP configuration, which device type is used as a cache only device?

    A. R21
    B. R22
    C. R11
    D. Standard Clone

  • Question 87:

    What is a characteristic of VMAX 40K Power Vault Hypers (PVDs)?

    A. PVDs are 9 GB in size.
    B. There are two PVDs per physical disk drive.
    C. Space is allocated for PVDs in Global Memory.
    D. PVDs are 5 GB in size.

  • Question 88:

    You are configuring SRDF in a VMAX 10K for a customer. Which type of SRDF Directors can you use in the SymmWin Directors Map?

    A. RF, RE
    B. EF, RF
    C. RA, RE
    D. RA, EF

  • Question 89:

    While running the Backend Cabling Verification script, the LEDs do not match the SymmWin graphic. It halts with a message that there is a cabling error and advises moving cables. Which service engagement would require PSE intervention prior to moving the cables?

    A. Data center move
    B. Installation
    C. DAE addition
    D. Storage bay addition

  • Question 90:

    Which FRU replacements are supported by Simplified SymmWin?

    A. MIBE and DAE
    B. Engine and DAE
    C. DAE and Multiple SPS
    D. Multiple SPS and Engine

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your E20-616 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.