Exam Details

  • Exam Code
    :500-920
  • Exam Name
    :Cisco Data Center Unified Computing Infrastructure Troubleshooting (DCITUC)
  • Certification
    :Cisco Channel Partner Data Center
  • Vendor
    :Cisco
  • Total Questions
    :40 Q&As
  • Last Updated
    :May 06, 2024

Cisco Cisco Channel Partner Data Center 500-920 Questions & Answers

  • Question 1:

    An overvoltage condition has occurred on a UCS server However the Cisco IMC System Event Log (SEL) file is full

    What is the resulting fault logging action?

    A. The newest entry in the SEL will be overwritten by the overvoltage condition event.

    B. The oldest entry in the SEL will be overwritten by the overvoltage condition event

    C. The SEL is not used to record server related events, such as overvoltage conditions.

    D. The overvoltage condition event will not be recorded in the SEL.

  • Question 2:

    What is the likely cause of an intermittent SAN Boot fails?

    A. Misconfigured SAN boot target in the boot policy of the service profile

    B. LUN ID Mismatch

    C. FCoE used instead of FC

    D. Wrong boot order in the service profile

  • Question 3:

    Which two interfaces allow access to Cisco UCS Manager? (Choose two )

    A. Cisco KVM

    B. Cisco UCS Manager XML API

    C. Cisco IMC

    D. Cisco UCS Manager GUI

  • Question 4:

    Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )

    A. Connect Fl-A to the IOM B of each chassis

    B. Connect Fl-B to IOM A and IOM B in each chassis

    C. Connect Fl-A to the IOM A of each chassis

    D. Connect Fl-A to IOM A and IOM B in each chassis

    E. Connect Fl-B to the IOM A of each chassis

    F. Connect Fl-B to the IOM B of each chassis

  • Question 5:

    Which statement is true when using SPAN for Fibre Channel (FC) Traffic?

    A. FC port on Cisco UCS 6238UP can be used as a SPAN source

    B. When defining FC uplink port as the SPAN destination, system will automatically stop using that port as an uplink port

    C. Any port can be used as a SPAN destination port Even if it is defined as Eth uplink port it will be automatically converted to FC uplink port

    D. For FC SPAN sessions we do not have to specifically enable the monitoring session

  • Question 6:

    In a Cisco UCS Manager, if all KVM sessions to each server fail to start, what is likely causing the problem?

    A. Cisco UCS Manager has a problem

    B. The Fabric Interconnect to which you are connected has a problem

    C. The I/O Modules in the chassis are the problem

    D. The workstation you are using to connect to the KVM session is the problem

  • Question 7:

    A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?

    A. No uplinks are active into the data center.

    B. The links to the chassis are not enabled

    C. The HA plugin has not been installed in UCS Manager

    D. The UCS-FI-HA license has not been activated in UCS Manager

  • Question 8:

    In order to create an Inband Profile for Cisco Integrated Management Controller (IMC) connectivity, what do you need to perform first?

    A. Create a Management IP Pool, a MAC Address Pool, and a VLAN Pool

    B. Create an IPMI Policy

    C. Create a Service Profile

    D. Create different VLANs, with different VLAN IDs

    E. Create a Management IP Pool, a VLAN. and a VLAN Group

  • Question 9:

    Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?

    A. Server Port

    B. Uplink Port

    C. Direct Connect Port

    D. Service Profile Port

  • Question 10:

    When it comes to pinning vNIC traffic from a UCS Server to the Fabric Interconnect uplink what configuration can you perform?

    A. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect

    B. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect

    C. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect

    D. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the same Fabric Interconnect

    E. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only Cisco exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your 500-920 exam preparations and Cisco certification application, do not hesitate to visit our Vcedump.com to find your solutions here.