  • Question 11:

    For two UPS5000-E (50 kA power module) 150 kVA with 2+0 rack redundancy, a () general input switch is required for the general input power distribution cabinet.

    A. 250 A
    B. 320 A
    C. 500 A
    D. 630 A

  • Question 12:

    Assuming that the discharge power specified in a battery specification is [email protected]@15min, if the system load requirement is 1400 W, () battery strings shall be configured.

    A. 3
    B. 4
    C. 5

  • Question 13:

    A UPS with a high input power factor allows for effective power grid utilization and reduced power grid interference. The input power factor of the UPS2000-A series (1 kVA to 3 kVA) is ().

    A. 0.85
    B. 0.9
    C. 0.95
    D. 0.99

  • Question 14:

    Which of the following modules in the UPS5000-E (50 kVA power module) support online hot replacements? (Multiple Choice)

    A. Power module
    B. Control module
    C. Bypass module
    D. PDM

  • Question 15:

    Which of the following basic project information doesn't need to be entered manually before configuration quotation? ()

    A. Quotation No.
    B. Quotation name
    C. Representative office
    D. Customer name

  • Question 16:

    The UPS5000-A-4O0/500K has good scalability, supporting a maximum of Q to be used in parallel.

    A. 2
    B. 3
    C. 4
    D. 6

  • Question 17:

    The failure warning feature for the key components of a UPS system changes post-event maintenance to pre-event maintenance, protecting loads from unexpected power failures. Which of the following components of the UPS2000-G support failure warning? (Multiple Choice)

    A. Fan
    B. Bus capacitor
    C. Output capacitor
    D. Battery

  • Question 18:

    The UPS5000-E (25-125 kVA) power module height is (), and the system efficiency is ( ).

    A. 3U, 95.5%
    B. 3U, 96%
    C. 2U, 95.5%
    D. 2U, 96%

  • Question 19:

    According to related standards and regulations, the AC cable voltage drop must be within 3%. You are advised to control the AC cable voltage drop within () when designing the UPS system.

    A. 0.01
    B. 0.02
    C. 0.03
    D. 0.05

  • Question 20:

    The UPS5000-A 30-120 kVA can be wall-mounted.

    A. TRUE
    B. FALSE

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only Huawei exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your H19-311 exam preparations and Huawei certification application, do not hesitate to visit our Vcedump.com to find your solutions here.