  • Question 111:

    Which is true when designing a power system with factory-configured whips?

    A. The whips require splicing upon installation

    B. There is no need for wiring underneath a raised floor

    C. The power system can run continuously at 140% of its rated capacity

    D. A licensed electrician is required to install the twist lock connectors of the whips

  • Question 112:

    What is the main advantage of using a wider than standard enclosure (over 600 mm)?

    A. Supports more servers

    B. Provides additional U space

    C. Increases space for network cabling

    D. Improves strength for seismic applications

  • Question 113:

    What is the definition of a cable assembly?

    A. A set of cables twisted together

    B. A cable with a connector terminated onto both ends

    C. A 3-wire cable that is 12 feet (3.66 meters) in length

    D. A bare cable that is ready to be assembled with its connectors

  • Question 114:

    How does a rack-mounted side air distribution unit improve air flow?

    A. It pulls air from cold aisles and directs it to side equipment inlets.

    B. It pulls air from the sides of the enclosure and directs it through the top.

    C. It pulls air from the sides of the enclosure and directs it to the hot aisles.

    D. It pulls air from the raised floor and directs it through the sides of the enclosure.

  • Question 115:

    What are the two features of enclosures that optimize adaptability when reconfiguring room layouts?

    A. Fan trays

    B. Perforated doors

    C. Field-reversible doors

    D. Quick-release side panels

  • Question 116:

    What is one positive effect of using standardized racks / enclosures that are universally compatible with vendors' equipment?

    A. Improved monitoring

    B. Increased load capacity

    C. Mixing of hot and cold air

    D. Decreased lifecycle costs

  • Question 117:

    How do blanking panels improve cooling within an enclosure?

    A. By increasing the mixture of hot and cold air

    B. By increasing air intake through vented doors

    C. By directing exhaust heat into IT equipment intakes

    D. By limiting the recirculation of air into IT equipment

  • Question 118:

    Where should applications that use side-to-side cooling or high cable densities be installed?

    A. Seismic enclosure

    B. 600 mm enclosures

    C. 750 mm enclosures

    D. Wall-mount enclosures

  • Question 119:

    To formulate proper cooling patterns in data centers, how should racks be arranged?

    A. Alternating hot and cold aisles

    B. Organizing individual rows by application

    C. Placing hot spots in the corners of the room

    D. Segmenting hot aisles in one room and cold aisles in another

  • Question 120:

    What are three critical considerations when managing IT equipment operations at the rack level?

    (Choose three.)

    A. Sound insulation

    B. Security breaches

    C. Generator availability

    D. Status of rack PDUs

    E. Power conditions of rack PDUs

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only APC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your DU0-001 exam preparations and APC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.