Exam Details

  • Exam Code
    :1Y0-A26
  • Exam Name
    :Citrix XenServer 6.0 Administration
  • Certification
    :Popular Exams5
  • Vendor
    :home
  • Total Questions
    :125 Q&As
  • Last Updated
    :May 09, 2024

home Popular Exams5 1Y0-A26 Questions & Answers

  • Question 1:

    An administrator cloned a template into a virtual machine and then converted it back into a template. Which action must be performed on the disks to restore expected levels of disk performance?

    A. Run SysPrep

    B. Execute a fast clone

    C. Complete a full copy

    D. Suspend before cloning

  • Question 2:

    Scenario: In preparation for adding a new iSCSI SAN to the environment, an administrator needs to separate the storage traffic from the XenServer management traffic. The host is connected to the iSCSI SAN on the 192.168.30.0/24 subnet using NIC 3.

    What must the administrator create to separate the storage network traffic?

    A. A management interface

    B. An external network

    C. A bonded network

    D. A single-server private network

  • Question 3:

    Scenario: An administrator needs to install Windows Server 2008 R2 on a new virtual machine. The Windows Server 2008 R2 ISO file is located on a Windows share.

    Which storage repository does the administrator need to create to be able to mount the ISO file to the new virtual machine?

    A. iSCSI

    B. CIFS

    C. NFS ISO

    D. StorageLink

  • Question 4:

    An administrator needs to throttle traffic from the virtual print server because it has been impacting all virtual machines on the network.

    On which object should the QoS policy be configured?

    A. Network

    B. Global

    C. Server

    D. VM

  • Question 5:

    Scenario: A virtual machine that uses Provisioning services is accidentally deleted by an administrator. The administrator creates a new virtual machine from the same template that was used to create the virtual machine deleted. However, the virtual machine is NOT able to start up from the vDisk.

    What must the administrator do to resolve the issue?

    A. Assign the correct vDisk to the target device.

    B. Reconfigure the target device MAC address.

    C. Configure the target device to start up from vDisk.

    D. Create a target device for the new virtual machine.

  • Question 6:

    Scenario: An administrator is moving a XenServer host from the New York datacenter to the London datacenter. During the installation of XenServer, the default NTP settings were selected.

    How must the administrator ensure that the XenServer host has the correct time settings?

    A. Configure the time in the host BIOS.

    B. Change the time zone using the xsconsole.

    C. Configure the time zone in the ntp.conf file.

    D. Change the NTP servers to the London NTP servers.

  • Question 7:

    Scenario: An administrator is troubleshooting a Provisioning services environment. After the administrator configured a new version of the vDisk for 10 identical target devices all running on the same XenServer host, the administrator discovers that only the first target device started with the new vDisk configured. The other nine target devices failed to startup.

    What is one of the steps the administrator should take to resolve this issue?

    A. Configure the PXE Service.

    B. Configure the bootstrap file.

    C. Restart the Stream Service.

    D. Change the vDisk access mode.

  • Question 8:

    Scenario: An administrator is troubleshooting a Provisioning services farm that consists of two identical servers and 100 identical target devices. From the Provisioning Services Console the administrator notices that one of the provisioning servers has twice the amount of target devices connected compared with the other provisioning server. The vDisk used and the provisioning servers are configured to use high availability and load balancing.

    What should the administrator check to correct load balancing?

    A. Power Rating

    B. Bootstrap options

    C. vDisk access mode

    D. Offline database support

  • Question 9:

    An administrator of a Provisioning services environment notices that several of the target devices that are configured to use a vDisk on the provisioning server are randomly failing to start and shut down.

    What should the administrator check to prevent this issue from occurring?

    A. The SOAP Service is running.

    B. High availability is enabled on the vDisks.

    C. The target devices are configured to start up from hard disk.

    D. All network switch ports have spanning tree protocol disabled.

  • Question 10:

    Scenario: An administrator manages a XenServer resource pool consisting of six XenServer hosts. A Windows XP virtual machine runs on a shared NFS storage repository. The administrator needs to migrate the Windows XP virtual machine to another host but CANNOT.

    What must the administrator do to migrate the Windows XP virtual machine?

    A. Install XenServer Tools on the virtual machine.

    B. Suspend and then migrate the virtual machine.

    C. Enable multipathing on the virtual machine hard drive.

    D. Place the virtual machine on shared Fibre Channel or iSCSI storage repository.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only home exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your 1Y0-A26 exam preparations and home certification application, do not hesitate to visit our Vcedump.com to find your solutions here.